76. What Is The Method Of Determining Maximum Differential Pressure During Hydro Testing Of Shell And Tube Heat Exchangers?

user image

Abhishek Mishra

2 years ago

Mr. Richard Lee of Plumlee International Consulting usually heat exchangers have two sets of test pressures per side, one for strength tests, and the other for "operating" or "leak" tests. The strength tests are set by the design code and if you have the original design data sheets for your equipment then the information should be shown on these. If you do not then you will have to do the calculations yourself, the exact method will depend upon which design code you use, the most common one being TEMA (which uses the ANSI/ASME pressure vessel code for reference in this area).