101. What Type Of Flow Measurement Devices Is Best For Slurries?
Any device that restricts the flow to perform measurements is not recommended for slurries. These devices include orifices and dampeners. These devices can lead to liquid/solid separation and they can lead to excessive erosion. Instead, measuring devices that do not restrict the flow should be used. One example of such a device is the magnetic flow meter.